WindowFix

Leaks and damp, , 3 min read

Balcony door leak in Batumi: the threshold and the latch

Watch on Telegram (1:06)

Hello everyone.

A bit about floor level!

While our other useful materials are being prepared, we will share some side notes from our day-to-day work.
This is how today's repair went, because of a mistake first by the developer and then by the repair crew. In essence, all of this points to unprofessionalism, first of all on the developer's side. We won't even get into the fact that the windows and doors are aluminum profile with ordinary glass, which is exposed to rain and dust.

Why water was getting into the flat

The aluminum doors on this Batumi balcony sank below the balcony floor level after the finishing work, so the drainage holes that carry water running off the door ended up below the floor, where the water should have drained in such cases.

In the end, doing it the way it should be done would have been too expensive for the owner, so it was done the cheaper way.

The sealing gasket was fairly fresh, since the windows had only just been installed and the building has not been commissioned yet. However, water was also leaking into the room because the gaskets were not doing their job properly: the locking mechanism was not pressing them firmly against the strike plates, or was not engaging at all.

The leak was fixed by putting the strike plates back in their places and adjusting the locking mechanism for tighter pressure (winter setting). With good pressure, the rubber gaskets flattened and started to hold back both the water running off the door and the street noise.

But strictly speaking, the developer should have dealt with this by installing an extra profile at the bottom of the door opening to separate the balcony floor from the room floor better, raising the threshold, and laying the balcony screed with a slope away from the door, so the floor is higher on the door side and lower farther from the door, without blocking the drainage holes!

Energy-efficient glass units for hot summers

In Batumi the sun heats rooms badly, through the floors, furnishings and sunlight patches, so it is better to fit energy-efficient glass units that let daylight through without the heat. In summer this saves on electricity for air conditioning, and in winter they keep heat inside the room, cutting heating costs.

We know this glass unit formula and a few other things besides, and we can arrange all of it for you.

We replace windows or glass units with the right ones.
We do the job well!

How we check the result

We measure the results of glass unit replacement with specialist instruments we have on hand: a thermal imager, a moisture meter and a range of other measuring equipment. So we don't just say that things got better, we give you figures for temperature, humidity or noise.

Our strength is full competence in thermal energy audits.

This post first appeared on the WindowFix Telegram channel. Open the post on Telegram

Dealing with something similar?

A technician comes with a thermal camera, finds the cause and tells you what needs fixing and what can stay as it is.

We reply on Telegram within 5 minutes during business hours