Leaks and damp, , 4 min read
Open Heating Valve in Batumi and a 60,000 GEL Flood
An honest account of a real call-out to find a hidden leak in Batumi. In this case I first believed the "eyewitnesses", gave a wrong initial conclusion, then came back for a second inspection and found a simple cause that would otherwise have taken a long time to find without me.
Background: a 60,000 GEL flood.
The owner of a 2+1 flat contacted us. He had not been in Batumi for about a year, and when he returned he found the fresh renovation completely soaked: wet walls, a collapsed plasterboard ceiling, ruined furniture. The damage had already reached 60,000 GEL.
The source of the water was one floor up, in a flat with an unfinished renovation where a radiator failure had already been fixed earlier. When I arrived for the first inspection, the water was shut off everywhere, nothing was dripping anymore, and the surfaces had started to dry.
How I got misled on the first call-out
I started collecting the facts from people on site. Two things were stated to me with confidence:
- when water is supplied to the flat, the meter is spinning;
- the heating circuit is fully shut off and nobody has touched it.
Taking their word for it, I ruled out the heating and refused to pressure test. Why apply pressure if the meter was supposedly showing flow anyway?
I went through the flat with the thermal imager: in an area of the floor where the pipe runs crossed, the device showed an abnormal heat distribution which, combined with the "spinning meter", looked like a clear leak in the pipes. I marked the spot, handed over the result and left.
Without my involvement, the owners brought in an outside contractor (charging almost double the market rate and very fond of showing off) who opened the screed at the marked point. The pipes under the floor turned out to be completely dry inside their protective sleeves.
Second inspection: the answer was on the surface
Accusations started: "because of you they opened the floor." I could have brushed it off and left, but I came back to get to the bottom of it.
The logic came together within half an hour:
- The opened channel in the floor: dry on one side, wet on the other, and the water comes from the side where there are no pipes at all.
- Inspecting the neighbor downstairs in daylight: last time, in the dusk, the owner pointed to the leak spot imprecisely. This time the real location was visible and, most importantly, a clear rhythm of drips.
- The boiler on the balcony: I went out on the balcony and saw water dripping from the wall-mounted double-circuit boiler, at exactly the same rate as the drips at the neighbor's one floor below.
- Safety valve and pressure gauge: I followed the path of the drips and found the water was being discharged through the black outlet of the safety valve. I checked the boiler gauge: the heating circuit showed 3 bar, the same as the cold water supply pressure in the hallway.
- Cause of the flood: I checked the heating fill valve, and it was turned all the way to the open position, that is, fully open.
Water under pressure was constantly feeding into the heating circuit, the safety valve was discharging the excess straight down beneath the boiler, and right below that spot the pipes from the balcony ran into the floor of the flat. Water seeped drop by drop under the screed along the line, spread across the whole flat and steadily flooded the neighbor below.
Control check and result
I simply closed the fill valve, and within 30 seconds the dripping from the valve stopped.
Half an hour later we went down to the neighbor: the system was still under pressure, and nothing was dripping from the ceiling anymore. Then we shut off the main inlet valve for 15 minutes and opened it again. The meter did not move.
All the pipes in the floor are intact.
Someone who had been there earlier most likely opened the fill valve and left it that way, probably during the previous renovation.
The outside contractors had not even looked in that direction and were ready to keep opening the floors. I am sure that without this second call-out they would have looked for this simple mistake for a very long time. It is a good thing the renovation upstairs was not finished yet.
The main lesson for me (the third one of its kind): my main mistake on jobs like this is trusting people's words too much.
Statements like "it's definitely shut off there" and "the meter is definitely spinning" are no longer taken on trust. Only personal checks of every valve, every pressure reading and every instrument reading.
The full breakdown of the situation and footage from the site are in the video: