HumidityWindows fogging in Batumi. Window or ventilation?
Why condensation builds up on the glass unit in Batumi, how to diagnose yourself in 60 seconds, and when the fix is the window vs. the airflow.
In Batumi the winter humidity stays at 75–90% with temperatures of +5–12 °C. When warm, moist air from the room touches cold glass, the water vapour turns into water. That is condensation on the window. It is not a "window disease" in itself but an indicator: somewhere the balance is broken.
Three causes of condensation on windows in Batumi
- A cold glass unit
A thin 24 mm or old single-chamber unit with no low-E coating — the glass is colder than the dew point.
- Weak ventilation
The windows seal tightly, the extract does not pull, and the kitchen and bathroom "steam" into the rooms.
- Sources of moisture
Cooking, showering, plants, drying laundry, people breathing. 2 people = up to 2 L of water into the air per day.
In the morning, before airing out: run a finger along the windows. If only the bottom edge has fogged up, it is a local problem (a cold bridge, poor pressure). If the whole pane has fogged up, the problem is the air humidity in the flat.
Local fogging — the window
If condensation gathers only at the bottom or in the corners, it is fixed at the window. A full window replacement is almost never needed.
- Replace the perimeter gasket if cold drafts in along the bottom edge
- Insulate the installation seam from outside (the seam has often peeled away over 4–6 years)
- Switch to a low-E glass unit (low-emissivity glass + argon)
- Adjust the cam pressure to the "winter" setting
The whole pane fogs up — ventilation
If the entire pane has fogged up, the cause is over-humidified air in the flat. It is fixed not at the window but with ventilation.
- Air out regularly for 5 minutes per hour (not "wide open all day")
- Micro-ventilation in winter via the hardware handle (we set it up ourselves on the visit)
- The kitchen and bathroom extract — does it actually pull? Hold up a tissue.
- A trickle vent in the window — the cheapest solution, 80 GEL
Fogging INSIDE the glass unit — between the panes
A special case: water gathers not on the surface of the glass but inside the unit. That is a loss of seal. It is fixed only by replacing the glass unit (from 150 GEL/m²), but the window does not need replacing.
Order a thermal imaging diagnosis + moisture meterWindowFix winter package: a moisture check + reveal insulation from 240 GEL turnkey.Frequent questions on this topic
Why do windows in Batumi fog up more than in Tbilisi?
When should I replace the glass unit, and when is micro-ventilation enough?
Does a dehumidifier help?
Send a technician
We reply on Telegram within 5 minutes during business hours